To install the Eliwell SB655C:

| Code | Group | Function | Range | Repack Tip | | :--- | :--- | :--- | :--- | :--- | | | Setpoint | Target temperature | Lo to Hi | Default: 3°C for coolers | | Hy | Differential | Compressor hysteresis | 0.1 to 25.0°C | Energy saving: 2.0°C | | LS | Limits | Minimum setpoint | -50 to 150°C | Freezer: -25°C | | US | Limits | Maximum setpoint | -50 to 150°C | Cooler: +15°C | | dtE | Defrost | Defrost end type | tE (time) / tP (probe) | Use tP for energy savings | | dIt | Defrost | Interval time (hours) | 0 to 99 | 6h for freezers, 8h for coolers | | FSt | Fan | Fan stop temperature | -50 to 150°C | Evap temp lower than 4°C stops fan | eliwell sb655 c manual repack

Master Guide: Mastering the Eliwell SB655/C Universal Controller To install the Eliwell SB655C: | Code |